https://www.appalachianpower.com/lib/docs/builders/meter/AEP_Current_Transformer_spec_07-2024.pdf
American Electric Power Customer Owned Current Transformer Enclosures Specifications AEP Current Transformer spec 07-2024.docxx 1 Customer-Owned Current Transformer Enclosures used in AEP's service territories shall meet the requirements
... · Outdoor enclosures shall be rated Type 3R. · Current transformer enclosure shall be fitted with h ...
https://www.appalachianpower.com/lib/docs/builders/meter/AEPSpecMeterBase_08-25-2025.pdf
American Electric Power Customer-Owned Meter Socket Specifications Page 1 AEPSpecMeterBase_08-25-2025.docx Customer-owned meter sockets used in AEP's service territories shall meet the requirements listed below and shall be produced by one
... · Outdoor enclosures shall be rated Type 3R. Mounting bosses shall provide 0.125-inch minimum air s ...
https://www.appalachianpower.com/lib/docs/business/builders/NetMeteringWithAppalachianPowerInVirginia.pdf
Net Metering with Appalachian Power In Virginia A Quick Guide for Our Customers A word about interconnecting with us: We want to protect your home or business and the electric power grid that serves our communities. That's why we comply
... to be based on your standard rate schedule. However, you will only be billed for your "net" energy ...
https://www.appalachianpower.com/lib/docs/business/builders/NMIN06012020.pdf
1 Form NMIN Effective 03/01/2020 AGRICULTURAL NET METERING OR NET METERING INTERCONNECTION NOTIFICATION PURSUANT TO RULE 20 VAC 5-315-30 OF THE COMMISSION'S REGULATIONS GOVERNING NET ENERGY METERING, APPLICANT HEREBY GIVES NOTICE OF INTENT
... Manufacturer and Model: Rated Capacity in kilowatts: AC DC Inverter Manufacturer and Model: Battery ...
https://www.appalachianpower.com/lib/docs/builders/meter/WV/Typical320AmporLessOverheadService-2024.pdf
PROVIDE 18" MIN. OF ADDITIONAL CONDUCTOR BEYOND THE POINT OF ATTACHMENT OR WEATHERHEAD. SERVICE DROP CONDUCTORS MUST BE 3' FROM WINDOWS OR DOORS THAT OPEN. ENTRANCE CABLE OR PIPE MAST 1. THE ENTRANCE CABLE OR PIPE MAST MUST BE STRAPPED
... MAST INSTALLATIONS. SINGLE RATED CABLE SHALL NOT BE USED. 4. THE OVERHEAD SERVICE CONDUCTORS SHALL ...
https://www.appalachianpower.com/lib/docs/builders/meter/WV/TypicalSinglewideMobileHomeOverhead-2024.pdf
TRIPLEX ALUMINUM SERVICE DROP CABLE AND SECONDARY TO COMPANY POLE AT GROUND LINE 18' 20' 22' 25' 6" CONDUIT BUSHING MOBILE HOME CABLE TO FOUR CONDUCTOR MIN. 12'-0" WEATHERHEAD DISCONNECT DEVICE SERVICE EQUIPMENT AT GROUND LINE " 64 59 5 "
... IS REQUIRED. 6. SINGLE RATED 'USE' CABLE IS NOT PERMITTED. 7. THE SERVICE DISCONNECT SHALL HAVE ADD ...
https://www.appalachianpower.com/lib/docs/company/about/choice/VA/2022/annualupdates2022/2022-02%20Capacity%20Formula%20Update.pdf
Appalachian Power Company Input Statement 12 Months Ending 12/31/2021 (actuals) for 2022 Appalachian Power Company Schedule Description Amount Sheet / Tab Cell B-1 Production Billing kW B-2 Production System Peak Demand 4,885.7 WP-1 D15
... 0 WP-6c C39 Asset Retirement Costs 1,366,095 WP-6c C46-C44 TOTAL GENERAL PLANT 371,837,469 Intangib ...
https://www.appalachianpower.com/lib/docs/company/about/choice/VA/2023/annualupdates2023/2023%20Capacity%20Formula%20Update.pdf
Appalachian Power Company Input Statement 12 Months Ending 12/31/2023 (actuals) for 2024 Appalachian Power Company Schedule Description Amount Sheet / Tab Cell B-1 Production Billing kW B-2 Production System Peak Demand 4,663.7 WP-1 D15
... WP-6c C39 Asset Retirement Costs 1,386,653 WP-6c C46-C44 TOTAL GENERAL PLANT 627,643,206 Intangible ...
https://www.appalachianpower.com/lib/docs/company/about/choice/VA/2024/annualupdates2024/2024%20Capacity%20Formula%20Update.pdf
Appalachian Power Company Input Statement 12 Months Ending 12/31/2024 (actuals) for 2025 Appalachian Power Company Schedule Description Amount Sheet / Tab Cell B-1 Production Billing kW B-2 Production System Peak Demand 4,663.7 WP-1 D15
... WP-6c C39 Asset Retirement Costs 1,386,653 WP-6c C46-C44 TOTAL GENERAL PLANT 724,663,345 Intangible ...
https://www.appalachianpower.com/lib/docs/company/about/choice/VA/2021/annualupdates2021/Capacity%20Formula%20Update.pdf
Page 1 of 37 5/25/2021 AEP APCo VA 2020 Capacity Formula Update with links INPUT Appalachian Power Company Input Statement 12 Months Ending 12/31/2020 (actuals) for 2021 Appalachian Power Company Schedule Description Amount Sheet / Tab
... 0 WP-6c C39 Asset Retirement Costs 1,204,129 WP-6c C46-C44 TOTAL GENERAL PLANT 330,496,687 Intangib ...